Gloeioven - GLO

GLO 10/11-1G

Volume (l) 10
Tmax vacuum (°C) 900 (1.4841) / 1000 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 1800 x 850 x 1600
Transport weight
Complete system (kg) 500
Usable space
Ø x D (mm) 250 x 600
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time from 1100 - 100 °C (h) 18 (natural) / 2.5 (forced)
Connecting values
Vermogen (kW) 14
Voltage (V) 400 (3P)
Current (A) 3 x 25
Series fuse (A) 3 x 32
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 1-3
Max. inlet temperature (°C) 23
Gas supply
Nitrogen or Argon flow, others on request (l/h) 200-2000
Controller
Manual operation Eurotherm
Automatic operation Siemens

VGLO-TL 10/11-1G

Volume (l) 10
Tmax vacuum (°C) 600
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 1600 (open) x 1400 x 850
Transport weight
Complete system (kg) 500
Usable space
Ø x D (mm) 250 x 250
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time (h) 4 - 5
Connecting values
Vermogen (kW) 14
Voltage (V) 400 (3P)
Current (A) 3 x 25
Series fuse (A) 3 x 32
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 1-3
Max. inlet temperature (°C) 23
Gas supply
Nitrogen or Argon flow, others on request (l/h) 200-2000
Controller
Manual operation Eurotherm
Automatic operation Siemens

GLO 40/11-1G

Volume (l) 40
Tmax vacuum (°C) 900 (1.4841) / 1000 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 1900 x 1400 x 1800
Transport weight
Complete system (kg) 1200
Usable space
Ø x D (mm) 310 x 600
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time from 800 - 100 °C (h) 13 (natural) / 2 (forced)
Connecting values
Vermogen (kW) 25
Voltage (V) 400 (3P)
Current (A) 3 x 63
Series fuse (A) 3 x 80
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 1-3
Max. inlet temperature (°C) 23
Gas supply
Nitrogen or Argon flow, others on request (l/h) 200-2000
Controller
Manual operation Eurotherm with KP 300 panel
Automatic operation Siemens

GLO 75/11-1G

Volume (l) 75
Tmax vacuum (°C) 800 (1.4841) / 900 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2000 x 1600 x 1800
Transport weight
Complete system (kg) 1500
Usable space
Ø x D (mm) 400 x 800
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time (h) 7 - 9
Connecting values
Vermogen (kW) 40
Voltage (V) 400 (3P)
Current (A) 3 x 110
Series fuse (A) 3 x 160
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 1-3
Gas supply
Nitrogen or Argon flow, others on request (l/h) 200-2000
Controller
Manual operation Eurotherm with KP 300 panel
Automatic operation Siemens

GLO 120/11-1G

Volume (l) 120
Tmax vacuum (°C) 700 (1.4841) / 800 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2100 x 1800 x 2000
Transport weight
Complete system (kg) 2000
Usable space
Ø x D (mm) 500 x 940
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time from 900 - 100 °C (h) 17 (natural) / 4 (forced)
Connecting values
Vermogen (kW) 60
Voltage (V) 400 (3P)
Current (A) 3 x 67
Series fuse (A) 3 x 80
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 5-10
Max. inlet temperature (°C) 23
Gas supply
Nitrogen or Argon flow, others on request (l/h) 200-3000
Controller
Manual operation Eurotherm with KP 300 panel
Automatic operation Siemens

GLO 260/11-1G

Volume (l) 260
Tmax vacuum (°C) 600 (1.4841) / 750 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2300 x 2000 x 2800
Transport weight
Complete system (kg) 2500
Usable space
Ø x D (mm) 640 x 1100
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052 ± 5
Max. heat-up rate (K/min) 10
Cooling time (h) 10 - 12
Connecting values
Vermogen (kW) 70
Voltage (V) 400 (3P)
Current (A) 3 x 110
Series fuse (A) 3 x 125
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min) 10-15
Max. inlet temperature (°C) 23
Gas supply
Nitrogen or Argon flow, others on request (l/h) 300-3000
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 400/11-1G

Volume (l) 400
Tmax vacuum (°C) 600 (1.4841) / 750 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2300 x 2000 x 3500
Transport weight
Complete system (kg) 3000
Usable space
Ø x D (mm) 640 x 1500
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 80
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 550/11-1G

Volume (l) 550
Tmax vacuum (°C) 600 (1.4841) / 750 (Inconel)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2300 x 2000 x 4000
Transport weight
Complete system (kg) 3300
Usable space
Ø x D (mm) 640 x 2200
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 90
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 600/11-1G

Volume (l) 600
Tmax vacuum (°C) 500 (1.4841)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2500 x 2300 x 3500
Transport weight
Complete system (kg) 3800
Usable space
Ø x D (mm) 800 x 1800
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 95
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 850/11-1G

Volume (l) 850
Tmax vacuum (°C) 500 (1.4841)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2500 x 2300 x 4000
Transport weight
Complete system (kg) 4300
Usable space
Ø x D (mm) 800 x 2300
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 100
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 950/11-1G

Volume (l) 950
Tmax vacuum (°C) 400 (1.4841)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2600 x 2400 x 3500
Transport weight
Complete system (kg) 4500
Usable space
Ø x D (mm) 1000 x 1700
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 110
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

GLO 1300/11-1G

Volume (l) 1300
Tmax vacuum (°C) 400 (1.4841)
Tmax atmospheric pressure (°C) 900 / 1100

[meer lezen] [minder lezen]

Afmetingen: Buiten H x B x D (mm) 2600 x 2400 x 4000
Transport weight
Complete system (kg) 5000
Usable space
Ø x D (mm) 1000 x 2400
Thermal values
-Delta-T between 300 and 1100°C (K) according to DIN 17052
Max. heat-up rate (K/min)
Cooling time (h)
Connecting values
Vermogen (kW) 120
Voltage (V)
Current (A)
Series fuse (A)
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit ruw, fijn of hoog vacuum
Cooling water required
Flow (l/min)
Max. inlet temperature (°C)
Gas supply
Nitrogen or Argon flow, others on request (l/h)
Controller
Manual operation Eurotherm Mini 8
Automatic operation Siemens

Onder voorbehoud van technische wijzigingen en eventuele fouten